3 4 npt opening accepts 80 fill with a float switch shut off device.
Refrigerant recovery tank valves.
Purge the hoses of air loosen and unseat the hose connected to the recovery tank until refrigerant is present and then retighten.
The valve is 1 2 acme fittings for mobile applications and is ported red vapor blue liquid.
Relief valve for half ton portable refrigerant tanks.
30lb 50lb 100lb 250lb.
Vapor recovery takes more time than.
The colors designate the different forms of refrigerant they recover.
Cylinder working pressure up to 260 psi.
Red valve knob involves vapor the red valve is a vapor valve used to recover refrigerant in a vapor state.
Solid brass construction for durability and long life.
Open the high side of the manifold for liquid recovery.
Constructed with a y valve for liquid and vapor.
At the hvac gauges and recovery machine you should see the pressure begin to drop as the refrigerant goes into he recovery tank.
Flame king refrigerant recovery cylinder tank reusable dot compliant y valve liquid vapor 30 lb pound 4 7 out of 5 stars 328 amazon s choice for r134a recovery tank.
For 1 npt tank connection.
Refrigerant tank 1 4 flare y valve assembly for 30 or 50 pound cylinders.
Refrigerant cylinders store and stack efficiently and safely with any manufacturer s refrigerant recovery 30lb.
Refrigerant tank 1 2 acme y valve assembly for 30 or 50 pound cylinders.
Set the recovery machine to recover.
Flame king s 30 pound refrigerant recovery cylinder is powder coated for high gloss and a durable finish.
The recovery tank valve along with all other valves should be open the recovery machine can be turned on.
The valve is 1 4 flare fittings for mobile or hvac applications and is ported red vapor blue liquid.
3 4 npt port v20429 manchester refrigerant tank valve assy dual port 600 psi 3 4 mpt fittings.
3 4 npt port refrigerant tank 1 4 flare tank y valve assembly blue vapor red liquid.
Solid brass construction for durability and long life.
One time fill one time fill means that once refrigerant has been put into the cylinder and then removed the cylinder may no longer be used for further recovery operations.
Ez one shot cylinders use dot 39 disposable cylinder technology to provide an inexpensive lightweight cylinder for use in one time fill recovery situations.
Used in conjunction with vapor and liquid recovery valve sets.
The tank s collar is designed for ease of handling.
Fully open the vapor valve on the recovery.
Start to discharge pressure.
Up to 1000 lb.
Standard refrigerant recovery tanks come equipped with both red and blue valves located at the top of the tank.
Be sure to watch the scale as to not overfill the recovery tank a tank should never be filled pass 80 percent.